Article 220 · screening

Estimate the dwelling service load.

Standard-method shape: 3 VA per square foot, small-appliance circuits, laundry, then the 3,000 VA / 35% split. Range and dryer use the VA you enter, not the demand tables.

Input values to calculate

Calculated results

General lighting and circuits
9,900 VA
After demand factor
5,415 VA
Fixed appliances
4,500 VA
Calculated load
29,215 VA · 121.7 A
Suggested service
125 A
Report calculation

What this sheet does

  1. You enter the floor area and the large loads in the house.
  2. Lighting starts at 3 VA for each square foot, plus 1,500 VA for each small-appliance circuit and the laundry circuit if you leave it on.
  3. The first 3,000 VA of that group is counted in full. Everything above 3,000 VA is counted at 35%.
  4. Fixed appliances, the dryer, and the range are added from the VA you type.
  5. Heating and cooling are not both added. The sheet keeps the larger one, then adds the largest motor.
  6. The total is turned into amps at 240 volts, then a suggested service size.